Volkswagen Golf/Jetta 2 manual
Automatic air cleaner temperature control - testingFuel and exhaust systems - Digifant fuel injection / Automatic air cleaner temperature control - testing
1 Disconnect the hose from the vacuum unit then remove the air cleaner cover and element.
2 Check that the flap in the lower body is closing the warm air inlet.
3 Suck on the vacuum hose and check that the flap moves freely to close the cold air inlet.
4 Flap operation may be checked with the engine idling by extending the vacuum hose and positioning a thermometer by the temperature regulator. Below 20°C, the cold air inlet must be closed. Above 30°C, the warm air inlet must be closed. Between 20°C and 30°C, the flap should be positioned midway so that both inlets are open.
5 Refit the air cleaner element and cover, then reconnect the hose.